´Ü¿­ ij½ºÅ¸ºí

  • °³¿ä

  • ´Ü¿­ ij½ºÅ¸ºíÀº ³»¿­¼ºÀÌ ³ô°í ¿­ÀüµµÀ²ÀÌ ³·Àº °æ·®°ñÀç¿Í ³»È­¼º ¾Ë·ç¹Ì³ª ½Ã¸àÆ®¸¦ »ç¿ëÇÏ¿© Á¦Á¶ÇÑ ¼ö°æ¼º ³»È­Àç·Î¼­ ³»¿­¼º°ú ´Ü¿­¼ºÀ» µ¿½Ã¿¡ ±¸ºñÇÏ´Â Á¦Ç°ÀÔ´Ï´Ù. µû¶ó¼­ ´Ü¿­ ij½ºÅ¸ºíÀº ³»È­¼º°ú ´õºÒ¾î ±¸Á¶Ã¼ÀÇ ¿­È¿À² Çâ»óÀÌ ÁÖ¸ñÀûÀ̹ǷΠÃà·Î½Ã¿¡´Â ·Îº®À¸·Î ºÎÅÍÀÇ ¹ß¿­·®°ú Ãà¿­·® ¹× ·Î³» ¿ÂµµµîÀ» ÃæºÐÈ÷ °í·ÁÇÏ¿© ÀûÀýÇÑ Á¦Ç°À» ¼±Á¤ÇÏ¿©¾ß ÇÕ´Ï´Ù.

  • »ç¾ç

  • Properties

    INCT-170

    INCT-160

    INCT-140

    INCT-120

    INCT-120S

    INCT-110

    INCT-110S

    INCT-100

    INCT-100S

    Max. Service Temp. (¡É)

    1,700

    1,600

    1,400

    1,200

    1,200

    1,100

    1,100

    1,000

    1,000

    Material Required
    for Estimating(kg/§©)

    1,600

    1,500

    1,350

    1,150

    900

    1,150

    800

    1,250

    700

    Chemical
    Analysis(%)

    Al2O3
    SiO2

    93

    63

    50

    32

    34

    25

    30

    30

    30

    -

    28

    36

    43

    42

    55

    37

    50

    35

    Permanent
    Linear
    Change
    (%)

    110¡É¥¹24hrs
    1,100¡É¥¹3hrs
    1,350¡É¥¹3hrs
    1,500¡É¥¹3hrs

    -0.03

    -0.03

    -0.06

    -0.06

    -0.06

    -0.06

    -0.06

    -0.06

    -0.06

    -

    -0.05

    -0.25

    0.10

    -0.35

    -0.40

    -0.80

    at 800¡É

    at 800¡É

    -0.50

    0.50

    -

    -

    -

    -

    -

    -0.6

    -0.8

    0.50

    -

    -

    -

    -

    -

    -

    -

    -

    Cold
    Crushing
    Strength
    (kg/§¨)

    110¡É¥¹24hrs
    1,000¡É¥¹3hrs
    1,350¡É¥¹3hrs
    1,500¡É¥¹3hrs

    110

    100

    75

    60

    35

    60

    25

    60

    20

    -

    -

    40

    30

    30

    30

    20

    50

    15

    60

    50

    40

    30

    30

    40

    25

    -

    -

    110

    110

    -

    -

    -

    -

    -

    -

    -

    Modulus
    of
    Rupture
    (kg/§¨)

    110¡É¥¹24hrs
    1,000¡É¥¹3hrs
    1,350¡É¥¹3hrs
    1,500¡É¥¹3hrs

    35

    30

    25

    20

    20

    20

    10

    20

    15

    -

    -

    15

    15

    10

    15

    10

    15

    10

    20

    20

    15

    15

    10

    15

    10

    -

    -

    35

    35

    -

    -

    -

    -

    -

    -

    -

    Thermal
    Conductivity
    (kal/m,h,¡É)

    260¡É
    540¡É
    800¡É

    0.76

    0.52

    0.34

    0.26

    0.20

    0.26

    0.14

    0.25

    0.13

    0.90

    0.57

    0.38

    0.32

    0.24

    0.28

    0.17

    0.28

    0.15

    0.95

    0.64

    0.42

    0.36

    0.28

    0.36

    0.21

    0.31

    0.21

    Water Required for Casting(%)

    15 ~ 20

    20 ~ 25

    30 ~ 40

    30 ~ 40

    40 ~ 50

    35 ~ 45

    50 ~ 60

    30 ~ 40

    60 ~ 70

    Installation Method

    Casting , Trowelling

    Applications

    Boiler
    Lining & Back up of General Kiln & Furnace
    Petrochemical Industry